Tower Specifications

Aquavista Tower is designed to showcase a professional and modern image for today's smart business. Finishes and materials have been selected for their aesthetic appeal and to minimise maintenance.

Structure

  • Reinforced concrete and structural steel

Façade

  • High performance vision glazing
  • Colour backed glass and composite aluminium cladding
  • Metal feature cladding
  • Exposed concrete with applied textured paint finish

Lobby

  • Ground floor entry opens to Docklands Drive with a minimum 3-metre high clearance
  • Basalt floor tiles with honed finish
  • Automatic sliding doors of frameless toughened glass and frameless swing doors with top and bottom rails
  • Lift door reveals finished in custom designed stainless steel
  • Concierge/reception desk
  • 2 custom designed electronic touch screen tenant directories 
  • Specialised feature lighting to entry lobby
  • Lockable mail box for each office suite

Ground floor retail tenancies

  • Shop fronts frameless clear toughened glass with glass mullions where required
  • Some shop fronts feature aluminium framed system

Lifts

  • 3 passenger lifts serve Level 7 car park and all office floors
  • 2 passenger lifts serve the public car park Levels 2 to 6
  • Office lift car interiors include timber veneer panelling finished on all edges with stainless steel angles
  • Rear wall to office lift car includes a mirror above polished stainless steel handrail
  • Office lift car and lobby floors finished with stone tiles

Gymnasium

  • Fitted gymnasium comprising exercise equipment and steam room
  • Change room facilities

Toilets and other facilities

  • Ground floor is served by 1 female toilet, 1 male toilet and 1 unisex disabled toilet facility
  • Level 2 gymnasium served by separate female and male change rooms each comprising lockers, 2 toilets and 5 showers; and a unisex disabled change room comprising 1 toilet and 1 shower
  • Each office level served by 3 male toilets and 3 male urinals, 4 female toilets and 1 unisex disabled toilet
  • Toilet finishes include full height Carrara marble tile walls, honed basalt floor tiles and stone vanity shelves over wall mounted hand basins

Kitchen facilities

  • Each office level served by 1 kitchenette that includes sink with boiling water tap, integrated waste bin, integrated under bench refrigerator and microwave with convection oven mode

Inter suite walls

  • Steel studwork with painted plasterboard finish to both sides

Painting

  • All internal plasterboard walls painted in satin acrylic finish
  • Amenities painted in semi gloss acrylic

Carpets

  • Commercial quality 100% wool carpet in all office areas

Ceilings

  • Pre-finished white acoustic ceiling tiles in 2-way exposed metal ‘T' bar suspension system

Lighting

  • Recessed fluorescent fittings to office areas
  • Low voltage lighting to amenity areas
  • Fluorescent fittings to car park areas
  • Feature lighting to entry lobby
  • Requisite emergency lighting throughout

Power

  • Each suite provided with a switchboard for control of light and power

Communications

  • 4 X 4 pair CAT6 communication cables provided to each tenancy for provision of internet access, iPort system and telecommunications
  • Master Antenna Television (MATV) Distribution System to each communications riser for future extension by tenants

Air conditioning

  • Reverse cycle packaged air conditioning units located in the ceiling space of each office tenancy and linked to building's air conditioning plant
  • Each office tenancy provided with a dedicated control and thermal zone

Fire services

  • Sprinkler protection in general compliance with AS 2118 provided for car park, podium and all office levels
  • Hydrant and hose reel system providing coverage to all areas throughout the building
  • Smoke detection and alarm system installed wherever stipulated in Building Code of Australia requirements

Security

  • Car park entrance/exit, passenger lifts and ground floor reception areas monitored by closed circuit television surveillance
  • Ground floor entrance lobby and Level 6 office car park gate fitted with electronic security access system
  • Entry to the office building after hours by security card

Car park

  • Floor and column construction of reinforced concrete
  • Line marking to all spaces
  • Car park levels have natural ventilation

Bicycles

  • Bicycle storage area located on Level 2 adjacent gymnasium and change room area

Storage

  • Chain wire mesh enclosures and/or block work enclosures allocated to some office suites

Terrace areas (if applicable)

  • Paved with ceramic tiles
  • Handrail and balustrade aluminium with inset panels of toughened glass